Item Specification

Max power consumption

Tested—125 W

Theoretical—150 W

NOTE:

The theoretical max power consumption, greater than the tested max power consumption, is the upper
power consumption threshold defined for the SAP to prevent power module overloading. You must use the
theoretical max power consumption, rather than the tested max power consumption, to calculate the total

power consumption for managing power modules and determining power module numbers.

LEDs

Table 50 LED description

LED Status Description

RUN
(Green)

Off

No power input is available or the SAP-24GBP has failed.

Slow flashing (1 Hz) The SAP-24GBP is operating correctly.

Fast flashing (8 Hz)

System software image is being loaded (in this case, never power
off the device or hot-swap the SAP-24GBP; otherwise, the
SAP-24GBP might be damaged).

SFP 0 to SFP 23
(Yellow/green)

Off

No link is present or the cable is faulty.

Steady green

A 1000 Mbps link is present

Flashing green

Data is being received or transmitted at 1000 Mbps.

Steady yellow

A 100 Mbps link is present.

Flashing yellow

Data is being received or transmitted at 100 Mbps.

Interface specifications

Table 51 Interface specifications

Item Specification

Connector type

SFP

Number of interfaces 24

Interface standards

802.3, 802.3u, and 802.3ab

Supported frame
format

Ethernet_II

Ethernet_SNAP

Optical
transmit

power

Type Short

distance

Medium
distance

Long distance

Long distance

Ultra-long
distance

Min.

–9.5 dBm

–9 dBm

–2 dBm

–4 dBm

–4 dBm

Max.

0 dBm

–3 dBm

5 dBm

1 dBm

2 dBm

Receiving sensitivity

–17 dBm

–20 dBm

–23 dBm

–21 dBm

–22 dBm

Central wavelength

850 nm

1310 nm

1310 nm

1550 nm

1550 nm