Monitor module indicator leds – Grass Valley 8900NET v.3.2.2 User Manual

Page 17

Advertising
background image

8900NET Instruction Manual

17

Power Up

Monitor Module Indicator LEDs

The possible LED status and conditions indicated are shown in

Table 1

.

Table 1. Indicator LEDs and Conditions Indicated

LED

LED State

Condition

POWER
(green)

Off

Power is off or on-board regulator has failed

On continuously

Module is powered

TEMP

(red)

Off

Frame temperature is within specified parameters

On continuously

Over-temperature condition detected in frame

PS2

(red)

Off

Normal operation or alarm disabled

On continuously

Power supply 2 is present and reporting an alarm condition

PS1

(red)

Off

Normal operation or alarm disabled

On continuously

Power supply 1 is present and reporting an alarm condition

FAN

(red)

Off

Normal operation or alarm disabled

On continuously

One or more fans in the front cover assembly is not rotating

MOD
(red)

Off

Normal operation or alarm disabled

On continuously

Module health bus is not disabled and one or more modules is reporting an internal
fault

Long continuous flashing

One or more modules is reporting a configuration error

FB

(red)

Off

Network module is communicating with modules on the frame bus

On

Internal frame bus communication failure

INHIB

(yellow)

Off

Normal operation or alarm disabled

On continuously

A non-compliant module in the frame has disabled the module health bus

FAULT

(red)

Off Normal

operation

On continuously

One of the on-board fault LEDs is illuminated or flashing

Flashing

Indicates the MOD (module health LED) is flashing

COMM

(yellow)

On

Indicates module is polling the devices on the internal frame communication bus

ETHER

(yellow)

On

Indicates active communication detected on the Ethernet bus

REM OVR

(yellow)

Off

All fault reporting is controlled by onboard configuration switches

On

Software overrides onboard configuration switches

Advertising