Grass Valley 8900NET v.3.2.2 User Manual

Page 64

Advertising
background image

64

8900NET Instruction Manual

Service

Event Messages From the Frame Are Not Being Displayed by NetCentral or
Another SNMP Manager Application

1.

Check that the frame is powered on and configured with an 8900NET
module on the Network.

2.

Check that the 8900NET module in the frame is loaded with software
version 2.1 or later.

Earlier versions of software do not support SNMP.

3.

Check that the SNMP Agent has been installed and configured on the
8900NET module.

View the 8900NET module

CONFIGURATION

page and note the event con-

figuration parameters, the

NET CARD EVENT REPORTS

form and

REPORT

DESTINATIONS

table.

If these are not visible, install the SNMP Agent per the instructions in
the manual.

4.

Check that the IP Address and Community Name for the SNMP
Manager has been assigned in the

REPORT DESTINATIONS

table and is

Active.

If there is no entry for the SNMP Manager in the Table, the SNMP
manager’s IP Address and Community name must be entered (see

8900NET Module Configuration Web Page on page 34

).

If the entry for the SNMP Manager is incorrect, it must be corrected,
activated, and the 8900NET module must be rebooted.

If the entry has been entered and the Status of the entry is reported

NOT IN SERVICE

, the Active operation for that entry must be selected,

applied and the 8900NET module must be rebooted.

If the entry has been entered and the Status of the entry is

NOT READY

,

the entry must be corrected, activated and the 8900NET module
must be rebooted.

If the entry has been entered and the Status of the entry is

ACTIVE

–PENDING REBOOT

, the 8900NET module must be rebooted.