Grass Valley 8900NET v.3.2.2 User Manual

Page 27

Advertising
background image

8900NET Instruction Manual

27

Using the 8900NET GUI

Figure 13. 8900NET GUI for Frame Control

Module Slot Status

Module Slot Status icons report one of the following (

Table 5

):

Table 5. Module Status Indicators

Icon

Color

Module

Status

Icon

Text

Indication

White

None

Empty

No module detected in slot.

Gray

No Comm No Comm Slot contains a legacy module which was not designed to support Frame

Bus communications with an 8900NET module.

Green

Pass

Module

Slot contains a fully Frame Bus capable module.

Yellow

Warning

Module

8900NET has detected a warning condition in module due to lack of input
signal or incomplete support for remote monitoring and control. Ability of
module to perform intended operation is limited.

Red

Fault

Module

8900NET has detected a fault condition in module. Fault may have been
communicated over the Frame Bus, or may indicate a failure of the module
to respond over the Frame Bus.

0612-12r2

The Links section lists the frame and its current modules. The selected link's Status
page is first displayed and the sub-list of links for the selection is opened. The sub-list
allows you to select a particular information page for the selected device.

Content display section displays the information page
for the selected frame or module (frame slot icons are also
active links).

Refresh button for manual
refresh of page

Advertising