Table 3 on – Grass Valley 8900NET v.3.2.2 User Manual

Page 20

Advertising
background image

20

8900NET Instruction Manual

Alarms and SNMP Monitoring

SNMP Trap severity can be one of three degrees:

Warning – a limitation in the module’s intended performance,

Alarm – a failure in communication with the module, or

Informational – a configuration change such as a switch setting.

The enabled SNMP traps will be reported to any SNMP manager that is
identified as an SNMP Report Destination in 8900NET configuration (see

8900NET Module Configuration Web Page on page 34

. Trap severity is

read-only hard-coded information that is interpreted and responded to by
the SNMP Manager software configuration.

The SNMP traps available on the Gecko 8900 frame and modules are out-
lined in

Table 3

. The web page location for the enable/disable controls are

listed as well as the SNMP trap reports available and their severity.

For the latest MIB (Management Information Base) files for the modular
control system, go to the Thomson Grass Valley public ftp site at:

ftp://ftp.thomsongrassvalley.com/pub/modular/

Table 3. 8900 Control System SNMP Traps Summary

Function

Web Page Control

SNMP Trap Report

Trap Severity

8900 Frame

Frame Configuration

Frame Bus Status

Alarm

Cover Status

Warning

Fan Status

Alarm

Module Health

Alarm

Frame Power Supply 1 and 2

Power Supply Configuration

Power Supply Fault

Alarm

Power Supply Removed

Warning

8900NET Module

8900NET Configuration

Net Card Status

Alarm

Hardware Switch

Informational

Media Modules

Media Module Slot Config

Slot Fault

Alarm

Module Removed

Warning

Signal Loss

Warning

Reference Loss

Warning

Advertising