Volume settings, Miscellaneous settings, Volume settings -13 miscellaneous settings -13 – Extron Electronics MLC 104 Plus Series User Manual

Page 53: Preliminar y

Advertising
background image

3-13

MLC 104 Plus Series • Software-based Configuration and Control

PRELIMINAR

Y

power off/power down command twice. The MLC must be configured to

send the IR power off command upon display power off button release (not at

the button press).

Send channel IR/232 as display powers up

— This setting ensures that the

inputs of the MLC and of the display device are coordinated when the display is

powered on.

Lockout I/O switching while display powers On or Off

— This feature prevents

input switching during the display power up and power down periods. This

I/O switching lockout is the same as SIS special command 53# (

page 4-33

). For

this command to work you must also set the power up and power down delay

periods (mentioned above).

Hold power-down button for two seconds

— This prevents shutting down the

display or projector by accidentally pressing the Display Off button. When this

feature is enabled, you must press and hold the front panel Display Off button

for two seconds before the power-off sequences can start. The corresponding SIS

command is 22#.

Volume settings

When adjusting the volume use

— For a projector, display, or audio output

device, volume is controlled by one of two methods: selecting a setting within

a specific range of values, or sending a simple command to increase or decrease

the volume by a fixed increment. Refer to the user’s manual for the display or

audio device to choose the best method for volume adjustment.

N

The power‑up volume limit is limited by the maximum volume setting (SIS

special command 47#). If the maximum volume (47# command) is set, the limit
audio level feature (SIS special command 11#) is automatically set to 25% of
the maximum volume (47#).

See pages 4‑33

and

4‑39

.

Volume encoder scaling factor (0-255)

— This feature allows you to slow

down the volume knob (the encoder) on the MLC’s front panel. This feature

addresses a scenario that occurs with some projectors that use range type

volume control. When the MLC’s knob controls projector volume, sometimes

the MLC sends the volume commands faster than the projector is able to detect

and process. When the projector does not detect some of the volume change

commands, a choppy volume ramp occurs.

Encoder scaling gives the programmer the ability to slow the knob down to

a speed the projector can handle. The drawback is that users must turns the

knob more times to change from minimum to maximum volume. It is up to

the user to find a balance between smooth audio ramping and the number of

knob turns needed to cover the volume range. This requires trial and error for

each projector exhibiting this problem.

Although this feature is mainly for range type volume control, it applies to any

range type command programmed to be executed by the volume knob. The

SIS special command 49# sets the encoder scaling factor.

Miscellaneous settings

Reset button statistics on upload

— For more information on button statistics

(which track how many times each front panel button is pressed), see

Statistics

” on page 3-17.

Upload enhanced web pages

— See “

Control

” on page 3-21 to see examples of

both basic and enhanced Web pages (which show photo-like versions of the

MLC’s and control modules’ front panels).

Enable/Disable IR Receiver

determine’s the MLC’s ability to receive IR signals

through the CM/IR/SCP port on the side panel. This feature is the same as the

65# SIS command (

page 4-40

).

Advertising