Power Mode cont.

Options include the following:

Ground-On:

The display always starts up in the ON state when the power pin is

set to ground, and it ignores all power commands from the IR, RS-232, and RS-

485. This setting will not take effect until you close the OSD.

Restore Previous:

The display returns to the previous power settings after any

power interruption.

Auto-On:

The display always starts up in the ON state when 28V is applied

(default when operating in Rosen RS-232 interface mode).

Auto-Off:

The display always starts up in the standby state when 28V is applied.

This setting requires a power command from the IR, RS-232, or RS-485 to turn the

display on.

Momentary:

The LCD power will toggle between on and off after the external

power discrete is momentarily grounded.

Open-On:

The display always starts up in the ON state when the power pin is

open (not grounded) and ignores all power commands from the IR, RS-232, and

RS-485. This setting will not take effect until you close the OSD.

Select Back and then press ENTER to return to the Technician Menu.
Press EXIT to exit the OSD.

10.2.2. Operation Mode

Use Operation mode to specify a default-operating mode. The Operation Mode setting

affects the OSD settings you will see and determines the factory default settings when

you perform a Factory Reset command.
From the Technician Menu, highlight Mode MenuOperation Mode, and then press
ENTER

.

Use the ▲▼ buttons to set the option, and then press ENTER. The screen will briefly go

black if you switch Operation Mode settings.
Options include the following:

Standard:

(Default) All video sources and functions are available. Power Mode will

default to Auto On.

Auto SDI:

The unit will always display SDI and use only a subset of OSD options.

The Power Mode will default to Ground On. See

Power Mode

on page

25

. If

Composite is connected, the unit will display Composite over SDI.

Table 3 Mode Menu settings

Operation Mode

Power Mode

Technician Menu

Standard

Auto On

Splash Screen &

Source Mode are ON

Auto SDI

Ground On

Splash Screen &

Source Mode are N/A