Measuring procedures, 1 measuring instruments, 1-1 voltmeter – Subaru Robin RGD3300H User Manual

Page 19: 1-2 ammeter, 1-3 frequency meter, 1-4 tester, Measuring instruments

Advertising
background image

– 16 –

7.

MEASURING PROCEDURES

7-1 MEASURING INSTRUMENTS

7-1-1 VOLTMETER

AC voltmeter is necessary. The approximate AC
voltage ranges of the voltmeters to be used for vari-
ous types of generators are as follows:

0 to 150 V: Type with an output voltage of 120 V

0 to 300 V: Type with an output voltage of 240 V

0 to 150 V, 0 to 300 V: Dual voltage type

7-1-2 AMMETER

AC ammeter is necessary. An AC ammeter with a
range that can be changed according to the current
rating of a given generator is most desirable.
(About 10 A, 20 A, 100 A)

7-1-3 FREQUENCY METER

Frequency range: About 45 to 65 Hz

NOTE: Be careful of the frequency meter’s

input voltage range.

7-1-4 TESTER

Used for measuring resistance, etc.

FOR AC

FOR AC

GENERATOR_GS2380.fm 16 ページ 2007年10月1日 月曜日 午前9時13分