■ Measure the resistance of field coil with a circuit

tester.

■ NORMAL RESISTANCE

[Remedy]

If the resistance is not normal, replace rotor with a new one.

(2)

CHECKING OF DIODES AND RESISTORS ON THE ROTOR

■ Unsolder and take out the diodes and a resistor from rotor.
■ Measure the resistance of diodes.

\

Each rotor has three diodes. Check the resistance of each diode.

■ Measure the resistance of surge absorber connected to the diode holder.

■ Check the magnetic force of permanent magnets molded in the rotor.

[Remedy]

(1)

If the magnetic force of rotor magnets is weak, or if the surge absorber is not good, replace the rotor
with a new one.

(2)

If the diode is not good, replace it with a new one.

CAUTION: In case the diode troubles are frequent, check the surge absorber because it

might be broken even if its resistance is normal (

). In such a case, replace the

rotor with a new one.

MODEL

RGD3300H

RGD5000H

Resistance

2.1

1.6

NORMAL RESISTANCE:

[Continuity exists.]

POLARITY OF
CIRCUIT TESTER

POLARITY OF
CIRCUIT TESTER

GENERATOR_GS2380.fm 44 ページ 2007年10月1日 月曜日 午前9時13分