21

power switch. The Power Injector receives power as soon as AC power is
applied.

For standard 48 volt power adapter (5014000247R) and line cord installations:

a

Connect RJ-45 CAT5e (or CAT6) Ethernet cable between the network data supply
(host) and the access point’s GE1/POE port.

b

Verify the power adapter is correctly rated according the country of operation.

c

Connect the power supply line cord to the power adapter.

d

Attach the power adapter cable into the power connector on the access point.

e

Plug the power adapter into an outlet.

For PoE-enabled switch or controller installations:

a

Connect an RJ-45 CAT5e (or CAT6) Ethernet cable between a PoE-enabled port
and the access point’s GE1/POE port.

b

Ensure the cable length from the PoE-enabled port to the access point does not
exceed 100 meters (333 ft).

c

Verify power is enabled on the PoE-enabled port.

CAUTION

Do not actually apply power to the AP until the cabling portion of the installation is complete.

6

Verify the behavior of the access point LEDs. For more information, see

“LED

Indicators” on page 26

.

7

Align the bottom of the ceiling T-bar with the back of the access point.

8

Orient the access point chassis by its length and the length of the ceiling T-bar.

9

Rotate the access point chassis 45 degrees clockwise.

10

Push the back of the access point chassis on to the bottom of the ceiling T-bar.