MFJ-1278B MULTI-MODE OPERATIONAL COMMANDS

CBELL ON/OFF

Mode: Packet Default: OFF


Parameters:

ON

Connect bell enabled


OFF

Connect bell disabled


This command is used to control whether an ASCII $O7 or CTRL-G (BELL) character is
sent as part of the connected message.

When set ON, the bell character immediately preceeds the asterisk portion of the connected
message, e.g.:

<BELL>*** Connected to: <callsign>


When CBELL is ON a tone will also be heard on the external speaker. A speaker must be
connected to the SPEAKER jack in the rear panel of the MFJ-1278B, in order to hear this
tone.


CBell ON/OFF

Mode: Pactor Default:OFF


Parameters:

ON

Allows the Connect bell to be heard over the monitor speaker.


OFF

Disallows the Connect bell to be heard over the monitor speaker.


This command is exactly the same as the CBELL command used in packet. This command
determines whether or not an ASCII $07 or CTRL-G (BELL) character is sent as part of the
connected message. This command must be ON, if the CHObell command is to be used,
otherwise the CHANGE OVER BELL will not work.

When the CBELL command is set to ON, the bell character immediately recedes the asterisk
portion of the connected message, e.g.

<BELL>*** Connected to: <CALLSIGN>

When CBELL is ON, and a connect is made a tone will be heard on the external speaker. A
speaker must be connected to the SPEAKER jack on the rear panel of the MFJ-1278B, in
order to hear this tone.