MFJ-1278B MULTI-MODE OPERATIONAL COMMANDS

RBITMASK $xx

Mode: RTTY/ASCII Default: 0


Parameters:

$xx 0 - $7F, specifying the bit inversion during receiving.


The RBITMASK command controls the bit inversion process applied to the received ASCII
and RTTY characters. Bit inversion is a simple means of encryption. RBITMASK should
be selected to match the inversion pattern of the station you are receiving.


RECONNECT call1 [VIA call2[,call3...,call9]]

Mode: Packet


Parameters:

call1

Callsign of TNC to be reconnected to.


call2

Optional callsign(s) of TNCs to be digipeated through. As many as eight digipeat

addresses can be specified.

RECONNECT is an immediate command. It may be used to change the path through which
you are currently connected to a station. It may only be used when your MFJ-1278B is
connected on the current stream to the station you wish to RECONNECT to.

Integrity of frames in flight between your station and the RECONNECTed station at the time
of RECONNECT is not assured.