MFJ-1278B MULTI-MODE OPERATIONAL COMMANDS

CONSTAMP ON/OFF

Mode: Packet Default: OFF


Parameters:

ON

Connect and disconnect status messages are time stamped.


OFF

Connect status messages are not time stamped.


This command enables time stamping of *** CONNECTED status messages. The date and
time information is then available for use by Bulletin Board programs or other computer
applications. The date and time must be set initially by the DAYTIME command before
time stamping will occur. The date format is determined by the DAYUSA command.

For example, if CONSTAMP is ON, DAYUSA is ON, and the date and time have been set,
a connect message might appear as follows.

*** CONNECTED to N2WX [05/28/85 16:28:31]



CONVERS

Mode: All Immediate Command


CONVERS is an immediate command, and will cause the MFJ-1278B to exit from
Command Mode into Converse Mode. Any link connections are not affected. Once in
Converse Mode, everything you type is packetized and transmitted over the radio. Typing
the Command Mode entry character returns the MFJ-1278B to Command Mode. See the
discussions of Converse Mode in Chapter 4 and Chapter 5.


CONVERSE

Mode: AMTOR Immediate Command


Switches from AMTOR command mode ( "a_cmd:" prompt) to the text transmission mode.
Use CONVERSE after a connection or FEC/SELCALL broadcast is begun to start
exchanging data.