MFJ-1278B MULTI-MODE APPENDIX H COMMAND SUMMARY

Command

Paramete
r

Default

Mode

Function

Page

LFADDALT

ON|OFF

on

RTTY

Enables the MFJ-1278B to go to the next
line when a <CR> character is received in
RTTY mode.

6-67

LFIGNORE

ON|OFF

off

Packet

Line feeds are ignored except in
transparent mode.

6-68

LISTEN

--

I-command

AMTOR

Used to monitor someone else's Mode A
AMTOR connection.

6-68

MAILbox

ON/OFF

off

Pactor

determines if Pactor Mailbox is on-line.

6-68

MAILBOX

ON|OFF

on

Packet

Enables the Packet personal mailbox.

6-69

MAILLED

ON|OFF

on

Packet

Controls the STA/MAIL LED. Flashes
when mail is presence.

6-70

MALL

ON|OFF

on

Packet

Determines the class of packets which are
monitored.

6-71

MARSMODE

n

0

RTTY/ASCII

Use with Promars command to set the
type of MARS QSO.

6-72

MATCH

ON|OFF

on

AMTOR

Used for selectively monitoring portions
of mode B FEC transmissions.

6-73

MAXFRAME

n

4

Packet

Sets the upper limit for the outstanding
packets that can occur at one time.

6-73

MAXSum

nn

30

Pactor

Specifies the number of cycles of error-
ladden information packets received.

6-74

MAXUp

nnn

10

Pactor

Specifies the number of good 100 baud
packets before a SPEEDUP is requested.

6-74

MBEGIN

cccc

<<>>

AMTOR

Allows the display of mode B
transmissions only after the reception of
the beginning of the signal.

6-74

MCOM

ON|OFF

off

Packet

Enables monitoring of connected and
disconnected packet when monitor is on.

6-75

MCON

ON|OFF

off

Packet

Allows the monitoring of other packets
while connected to another station.

6-75

MCTEXT

text

blank

Packet

Allows storing of text messages to be
stored for mailbox. Text is sent when
mailbox is connected.

6-76

MEND

cccc

nnnn

AMTOR

Used with MBEGIN and MATCH and the
mode B receiving end when the MEND
string is received

6-76.

MFILTER

n1-n4

$00

M-Packet

Allows you to eliminate certain characters
from received packets.

6-76

MHCLEAR

--

I-command

Packet

Clears the MHEARD list.

6-77

MHEARD

--

I-command

Packet

A list of all monitored packet stations.

6-77

MODE

--

I-command

All

Selects the operation mode of the MFJ-
1278B.

6-77

MNONAX25

ON|OFF

off

Packet

Allows MFJ-1278B to monitor non AX.25
packet.

6-78

MNONPRIN

ON|OFF

on

Packet

Determines whether monitored packets
containing non-printable characters are
monitored or discarded.

6-78