MFJ-1278B MULTI-MODE OPERATIONAL COMMANDS

CWCALL ssss

Mode: Amtor Default: blank


Where "ssss" are 15 characters sent as CW when you issue the ID character. The "ssss" text
is sent following the QRA ("The name of my station is ______") signal.

CWidmode nn: 0<=nn<=255

Mode: Pactor Default 0


Should CW identification be required, the MFJ-1278B now supports 8 CW identification
modes. Seven automatic modes are selected by the bit-mapped CWIDMODE parameter.
Bit positions within the CWIDMODE parameter enable timed cw id, cwid on incoming
events, cwid on outgoing events,
and any combination of the three for a total of 7 modes.

The timed mode requires some explanation. The counter controlling the transmission of the
timed CWID must be initially started at the beginning of each link with either the manual
"ID" command or one of the initial CWIDMODE features selected by CWIDMODE bits 1
or 2. A fully automatic CW ID is achieved by setting CWIDMODE to 3. Reduced levels of
automation are selected by other combinations. The eighth mode is manual cwid. Invoke
manual CWID by issuing the "ID" command. Also see IDTIME

The CWIDMODE command in Pactor is very complex and provides several combinations of
CWID. Below is an example of how CWIDMODE functions:

CWID/
MODE

On
Calling

On
Connect

On
Disc.

Man./
Auto

Comments

1

Man.
Only

Mode 1 is manual ID only

2

IRS

IRS

3

ISS,IRS

IRS

IRS

Auto
ISS,
ISR

Auto ID interval dependent on the
IDTIME setting

4

ISS

ISS

If ISS does changeover, and new ISS
disconnects, then the new ISS will ID

5

ISS

ISS

Auto
ISS
only

If ISS does changeover, then previous
ISS auto ID is Disabled

6

ISS

IRS

ISS,
IRS

Upon reciept of disconnect from ISS
and the disconnect appears on IRS
screen, the IRS will ID. After ID
from IRS, the ISS will ID

7

ISS, IRS

IRS

IRS,
ISS

Auto
ISS,
IRS

When ISS sends changeover, new ISS
AUTO ID enabled. Auto ID for
previous ISS is disabled. Disconnects
are handled the same as Mode 6