Mspeed (motor speed), Control function options, Fixture operations – High End Systems DL.3 User Manual

Page 202: Mspeed (motor speed) control function options, Control

Advertising
background image

CHAPTER 14

Fixture Motion Functions

180

DL.3 Digital Light User Manual

MSpeed (Motor Speed)

The MSpeed parameter adjusts the time required for a motor to complete movement when
changing from one position to another. MSpeed provides a method for all motors to reach their
target position at the same time, even though each motor may have different distances to
travel. MSpeed movement is extremely smooth because the fixture controls movements
independent of DMX refresh rates.

MSpeed times vary from 0.15 seconds to 252.7 seconds. In general, allowing the console to
crossfade the pan and tilt values for a DL.3 or DL.2 fixture is acceptable. However, extremely
slow movements may require the use of Mspeed instead of console crossfades. For a listing of
exact MSpeed times, see “Appendix B: MSpeed Conversion Table”.

Control Function Options

The Control parameter remotely initiates various fixture operations and allows access to the
internal-projector menu controls.

Fixture Operations

Note:

All of the following Fixture operation Control parameter settings (except

for MSpeed Off), require the Dimmer be closed (DMX Value = 0).

DMX Value

Range

Control Option Description

10-13

Disables Pan and Tilt MSpeed

20-28

Disables the LCD Display

30-38

Dims the LCD display

40-48

Enables the LCD display

50-58

Enables Preview Mode for the LCD display

60-68

Homes all the fixture mechanical functions

80-88

Manually turns the Lamp ON

90-98

Manually turns the Lamp OFF

120-130

Shuts down the fixture

145-149

Resets the Graphics Engine

150-155

Resets the Camera functions

160-168

Homes only the Pan and Tilt functions

170-178

Homes only the Focus, Zoom, and Dimmer components

Advertising