High End Systems DL.3 User Manual

Page 240

Advertising
background image

CHAPTER 17

Maintenance and Troubleshooting

218

DL.3 Digital Light User Manual

6. Remove the two philips pan screws securing the filter bracket and lift the filter unit off the

fixture.

7. Remove the bracket and remove the HEPA filter from filter housing. Inspect both the

prefilter and the HEPA filter.

8. A dirty prefitler can cause an early Service Filter warning. If the prefilter looks dirty, clean it

with water. Thoroughly dry the prefilter before proceeding.

9. If the HEPA filter is discolored with particulates, replace it with the part listed in “Related

Products and Accessories” on page 1-4.

Reassemble the Fixture

10. Reinstall the HEPA Filter with the rubber gasket

down.

11. Reattach the filter bracket with the two philips pan

screws.

12. Replace the prefilter over the bracket on velcro

tabs.

13. Replace the top cover, fastening it with the two

quarter-turn screws.

14. Carefully replace the rear bezel, making sure to

position (but do not force) the gasket against the
lamp cover located on the back of the projector.
and Relatch the rear bezel assembly.

Place HEPA
filter with gasket
against plenum

Gasket

Advertising