DMX Protocol

238

DL.3 Digital Light User Manual

10

NA

Control
Function*

Lamp OFF (80)

90-98

NA

0

0

Reserved

99-119

Shutdown (80)

120-130

Reserved

131-144

Graphics System Reset (80)

145-149

Camera Reset

150-155

Home Pan/Tilt (20)

160-168

Reserved

169

Home Focus/Zoom/Iris (20)

170-178

Reserved

179

Using the Projector’s Menu System

Projector Menu

180-184

NA

Projector Up arrow

185-188

Projector Down arrow

189-192

Projector Left arrow

193-196

Projector Right arrow

197-200

Store menu selection

201-204

Projector Floor Orientation

205-208

Projector Ceiling Orientation

209-212

Projector Front Projection

213-216

Projector Rear Projection

217-220

Changing Projector Inputs (Set Dimmer Channel = 0)

External RGBHV to Projector

221-224

NA

Graphics Engine to Projector (default)

225-228

Changing Graphics Engine Inputs (Set Dimmer Channel = 0)

S-Video In to Graphic Engine, Internal Camera to
Camera Out

229-232

NA

Internal Camera to Graphics Engine (default)

233-236

Setting Projector Lens Shift (Set Dimmer Channel = 0)

Lens Shift Engaged (100)

This feature is

available only in DL.3 fixtures.

237-240

Lens Shift Off (100)

This feature is available

only in DL.3 fixtures.

241-244

Setting SDI Switching Mode

Camera Routed to SDI Output (100)

This feature

is available only in DL.3 fixtures.

245-248

NA

SDI Input Routed to Capture Card (100)

This

feature is available only in DL.3 fixtures.

249-252

Reserved

253-255 99-100

Channel #

Function

Description

Value

Default

DL.3
DL.2

Axon

dec.

%

dec.

%

Active

Commands

*

To prevent inadvertent triggering, some Control Function options won’t activate until the value has been

held for a period of time. A number in parenthesis is the minimum number of consecutive times a DMX

value must be received from a controller before the operation begins.