Info tab, Info_hours, Info_version screen – High End Systems DL.3 User Manual

Page 57: Info_status tab, Info_hours info_version screen info_status tab

Advertising
background image

CHAPTER 3

The Digital Light Menu System

DL.3 Digital Light User Manual

35

Info Tab

The Info tab displays current fixture information such as hardware and software versions,
sensor status, total fixture and lamp hours, and DMX errors. You can also reset Lamp and
Fixture hours.

Info_Hours

The Hours tab displays the Lamp and Fixture
hours of operation since the last reset. Clicking
on the Reset button resets the associated
hours to zero. Lamp hours should be reset to
zero whenever a lamp is replaced.

Fixture Hours information is often used to
track fixture hours for a show or a rental
period. The number field displays the number
of hours the fixture has been operating since
the last reset. Pressing the Fixture Hours Reset
returns the value to 0.

Info_Version Screen

The Software Version field and Firmware
Version
field display software versions as:
V(Major).(Minor).(Build). The Unique ID
number identifies this specific unit for use in
synchronization applications. The Fixture
Name
field displays a name you assign in the
Content Management Application for easy
reference in developing your show. The IP
Address
is assigned to that unit by the router
or Auto IP. The Projector Type identifies the
model of the fixture’s internal projector.

Info_Status Tab

This screen displays status errors and warnings
on items including:

• Temperature
• Filter life
• Lamp life
• USB and Camera Communication
• USB Security

For more detailed information, see Chapter 17:
Maintenance and Troubleshooting.