Hayes Microcomputer Products DIVA T/A ISDN User Manual

Page 45

Advertising
background image

DIVA T/A ISDN Modem User’s Guide 45

Parameter

Description

Initial Billing Interval: Specifies the length of
the first billing interval (in seconds). For
example, if your provider charges a fixed $X for
the first 5 minutes enter 300.

Note: Set the timer to 0 disables it. The Billing
Interval timer is also, effectively disabled.

Default: 60 seconds.

Billing Interval: Specifies the increments your
Service Provider uses to bill subsequent usage of
your ISDN line (usage after the initial Billing
Interval expires). For example if your Provider
charges $Y per minute for each minute
following the Initial Billing Interval, enter 60.

Note: Setting the timer to 0 disables it. The
Initial Billing Interval remains in effect.

Default: 60 seconds.

1st B-channel

Delay before opening: Specify the amount of
time (in seconds) the throughput on your D-
channel must exceed the Opening Threshold
before the 1st B-channel is added to the AO/DI
connection.

For example, if you specify 5 seconds, and the
Opening Threshold is 70%, once the throughput
on the D-channel reaches 70%, there will be a
delay of 5 seconds before the 1st B-channel is
added to the AO/DI connection. If the
throughput drops below 70% during the 5
seconds, the 1st B-channel will not be added to
the connection.

Opening Threshold: Specify the threshold
(percentage) that the throughput on your D-
channel must exceed before the 1st B-channel is
added to the AO/DI connection.

Closing Threshold: Specify the threshold
(percentage) that the throughput on your B-
channel must be below before the 1st B-channel
is dropped from the AO/DI connection.

Note: This option is only available with AO/DI
support.