Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06

10

B. Clearances

0 in.

to floor

1 in. (25 mm) to side of appliance

(except at nailing flanges where it is 1/2 in. (13 mm))

1 in. (25 mm) to back

of appliance

Attic

Insulation

Shield

Ceiling Firestop

(ceiling)

(roof)

(attic)

(ceiling)

2 in. min.

(51 mm)

2 in. min.

(51 mm)

2 in. min.

(51 mm)

2 in. min.

(51 mm)

2 in. min.

(51 mm)

2 in. min.

(51 mm)

Must have 2 in. (51 mm)

minimum clearance

to header

Ceiling Firestop

Offset/Return with

hanger straps

Storm Collar

Roof Flashing

0 in. to level

of standoffs

Figure 3.2

Clearances to Combustible Materials

Fire Risk
• Comply with all minimum clearances to

combustibles as speci

¿ ed.

Failure to comply may cause

¿ re.

WARNING

Note: Chimney air kit is not shown, but required in Canada.