Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06

14

Handle up - open

Handle down - closed

Figure 4.4

Locating the Outside Air Control

Outlet placed

higher than 3 ft

below the

termination cap

Attic space

Garage or

combustible

liquids storage

Outlet blocked by

snow, leaves, etc.

Clear area

outside

house or in

ventilated

crawl space

YES

NO

NO

NO

NO

Use only duct materials specified
by manufacturer (preferably with
short run or mainly straight duct,
except small dip for cold air trap
which will help prevent flow of cold air).

Factory-built

fireplace

Figure 4.3

Outside Combustion Air Placement

3 ft min. from top of
uppermost chimney
section to air inlet.

Attic insulation shield
may be used to keep
insulation away from
chimney.

Ceiling firestop
on floor of attic.

Figure 4.2

Outside Air Inlet Locations

Note: Chimney air kit is required in Canada.