Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06

19

C. Assemble the Chimney Sections

Attach either a straight chimney section or an offset to the
top of the

¿ replace (depending on your installation require-

ment). Chimney sections are locked together by pushing
downward until the top section meets the stop bead on the
lower section.

The inner

À ue is placed to the inside of the À ue section below

it. The outer casing is placed outside the outer casing of the
chimney section below it. See Figure 5.4.

D. Install the Ceiling Firestops

Mark and cut an opening in the ceiling for the spacer being
used. See Figure 5.5.

Frame the opening with the same size lumber used in the
ceiling joists.

• Install the ceiling

¿ restop.

Note: The ceiling

¿ restop MUST be nailed to the bottom

of the ceiling joists EXCEPT when the space above is
uninsulated and the attic insulation shield is not being used
(see Figure 5.5). When the attic insulation shield is used
the ceiling

¿ restop may be above or below the joist of an

insulated ceiling.

Note: You must provide support for the pipe during con-
struction and check to be sure inadvertent loading has not
dislodged the chimney section from the

¿ replace or at any

chimney joint.

Note: Inner

À ue and outer liner sections cannot be disas-

sembled once locked together. Plan ahead to ensure the
proper installation height is achieved with the selected
chimney components.

• Ceiling

¿ restops must be used at ceiling/À oor.

• Chase construction requires ceiling

¿ restops at each

À oor or every 10 ft (3.05 m) of clear space.

• Use same dimensional lumber as joists.

Ceiling

¿ restop slows spread of ¿ re and reduces cold air

in

¿ ltration.

CAUTION

Figure 5.4

Assembling Chimney Sections

ROOM ABOVE (non-insulated ceiling)

ATTIC ABOVE (insulated ceiling)

B

A

Ceilng firestop from

bottom

Ceiling firestop from

top

When attic insulation

shield not used

Note:

Use same dimensional lumber for framing

ceiling firestop and joists.

Figure 5.5

Installing the Ceiling Firestop

Fire Risk

Do NOT install substitute or damaged
chimney components.
• MUST use chimney system described in

this manual.

• NO OTHER chimney components may

be used.

Substitute or damaged chimney components
may impair safe operation.

WARNING

Catalog #

A

B

in.

mm

in.

mm

FS538

17

432

17

432

FS540

17

432

26

660