A. Gas Log/Lighter Provisions

A certi

¿ ed gas log lighter or decorative gas log set can be

installed in this

¿ replace.

• Maximum input is 100,000 BTU/hr.

Decorative gas appliance must be certi

¿ ed to ANSI Z21.60

“Standard for Decorative Gas Appliances for Installation
in Vented Fireplaces”.

• Must be installed in accordance with the National Fuel

Gas Code, ANSI Z223.1.

• A log set must incorporate a gas shutoff.
• Log set requires the damper to be locked fully open.

Firebox

Repack
Insulation
Knockout

Combustible
Materials

Maintain air clearance
to combustibles.

Gas Line

Combustible materials
may be located at zero
clearance to gas line
beyond 4 in. (102 mm)
from fireplace side.

Gas Line

1-1/2 in.
(38 mm)
air space

Refractory

Seal with
fireplace mortar
or cement

4 in.

(102 mm)

Outer Shell
of Fireplace

Figure 7.1

Gas Line Installation

7

7

Accessories

Asphyxiation Risk

Damper must be locked open when gas logs
installed.

Gas

¿ re generates fumes.

WARNING

Fire Risk
• For use with solid wood fuel or decorative

gas appliance only.

• DO NOT install unvented gas logs.

WARNING

Knockouts are provided on both sides of the

¿ replace and in

refractories for 1/2 in. (13 mm) iron pipe.

• We recommend you seal refractory around pipe with

¿ replace mortar or cement.

• Repack insulation from the knockout around the pipe.
• Maintain 1-1/2 in. (38 mm) air space around the pipe for

4 in. (102 mm) beyond the

¿ replace.

• See Figure 7.1.

Fire Risk
Explosion Risk
Inspect appliance and components for

damage. Damaged parts may impair safe
operation.

• Do NOT install damaged components.
• Do NOT install incomplete components.
• Do NOT install substitute components

Report damaged parts to dealer.

WARNING