B. Using Offsets/Returns

To bypass any overhead obstructions, the chimney may be
offset using a 30-deg (SL430) offset/return.

An offset and return may be attached together or a chimney
section(s) may be used between an offset and return.

Perform the following steps to determine the correct chim-
ney component combination for your particular installation:

Measure how far the chimney needs to be shifted to enable
it to avoid the overhead obstacle. See Figure 5.3. Use
dimension “A” to determine chimney section required to
achieve the needed shift.

• After determining the offset dimension, refer to Table 5.2

and

¿ nd the “A” dimension closest to but not less than the

distance of shift needed for your installation.

• The “B” dimension that coincides with the “A” dimension

represents the required vertical clearance that is needed
to complete the offset and return.

• Read across the chart and

¿ nd the number of chimney

sections required and the model number of those particular
chimney parts.

Whenever the chimney penetrates a

À oor/ceiling, a ceiling

¿ restop must be installed.

The effective height of the

¿ replace assembly is measured

from the base of the

¿ replace to the top of the starter collar.

See Dimensions in Section 12.

Table 5.2

A

B

1-1/4 in. (32 mm

OVERLAP

Figure 5.3

Chimney Offset/Return

Example: Your “A” dimension from Figure 5.3
is 14 1/2 in. (368 mm). Using Table 5.2 the
dimension closest to, but not less than 14- /2
in. (368 mm) is 14 5/8 in. (371 mm) using a
30° offset/return. It is then determined from
the table that you would need 33 in. (838 mm)
(Dimension “B”) between the offset and return.
The chimney components that best

¿ t your

application are two SL412s.

Fire Risk
• Draft will be restricted if offset/returns

greater than 30° are used.

WARNING

A

B

SL406

SL412

SL418

SL436

SL448

in.

mm

in.

mm

3-7/8

98

14-1/2

368

-

-

-

-

-

6-1/4

159

18-5/8

473

1

-

-

-

-

9-1/4

235

23-3/4

603

-

1

-

-

-

12-1/4

311

29

737

-

-

1

-

-

14-5/8

371

33

838

-

2

-

-

-

17-5/8

448

38-1/4

972

-

1

1

-

-

21-1/4

540

44-5/8

1133

-

-

-

1

-

23-5/8

600

48-3/4

1238

1

-

-

1

-

27-1/4

692

55-3/4

1416

-

-

-

-

1

29-5/8

752

59

1499

1

-

-

-

1

32-5/8

829

64-1/4

1632

-

1

-

-

1

35-5/8

905

69-1/2

1765

-

-

1

-

1

38

965

73-5/8

1870

-

2

-

-

1

41

1041

78-3/4

2000

-

1

1

-

1

44-5/8

1133

85

2159

-

-

-

1

1

47

1194

89-1/8

2264

1

-

-

1

1

50-5/8

1286

95-1/2

2426

-

-

-

-

2

Proper assembly of air cooled chimney parts results in an overlap of chimney joints of
1-1/4 in. (32 mm). Effective length is built into this table.

¨

¨