Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06

6

Location of the

¿ replace and chimney will affect performance.

As shown in Figure 2.1 the chimney should:

• Be installed through the warm airspace enclosed by the

building envelope. This helps to produce more draft,
especially during lighting and die-down of the

¿ re.

• Penetrate the highest part of the roof. This minimizes the

effects of wind turbulence.

• Be located away from trees, adjacent structures, uneven

roof lines and other obstructions.

Offsets can restrict draft so their use should be minimized.
Consider the

¿ replace location relative to À oor and ceiling

and attic joists.

Recommended

Location

Marginal
Location

Location

Not

Recommended

Recommended

Location

Multi-level Roofs

Windward

Leeward

Outside Air Intake

Location

Not

Recommended

Figure 2.1

Recommended Chimney Locations