Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06

16

NOTE:

Chimney performance may vary.
Trees, buildings, roof lines and wind conditions affect

performance.

Chimney height may need adjustment if smoking or

overdraft occurs.

Chimney must extend
beyond combustible
roof structure

Maintain minimum
height of chimney
above roof

Additional
support for
tall chimneys

Install roof flashing
according to minimum
requirements

Maintain minimum
clearances to
combustibles as
specified

Offsets/returns
may not exceed
30° from vertical

Lock chimney
sections together
firmly to resist
movement

Ceiling firestops
are required where
chimney passes
through ceiling or
floor

Support straps for offsets/
returns must be secured
to adequate framing

Termination Cap

Storm Collar

Figure 5.1 Typical Chimney System - Guidelines for Chimney System Installation

5

5

Chimney Assembly