Troubleshooting – Heat & Glo Fireplace EXCLAIM-36T-C User Manual

Page 32

Advertising
background image

Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06

32

10

10

Troubleshooting

Another appliance in
home also exhausting
air (furnace, fan,
dryer, etc.)?

Air register from
furnace near
fireplace?

Doors opening
and closing?
Window closed
for start-up?

Outside air
closed?

Overhead fan
operating?

Overhanging
tree?

Bird's nest
or leaves in
termination
cap?

Structural
changes in
chimney area?

Creosote buildup
in flue?

Damper closed?

Stron

g w

in

ds

a

ro

un

d c

himney

term

ina

tio

n?

Unsealed
can lights?

Figure 10.1 Factory-built Fireplaces: Troubleshooting

This

¿ replace will operate correctly only if adequate ventila-

tion is provided to allow proper draft to the

¿ replace system.

Hearth & Home Technologies assumes no responsibility for
the improper performance of the

¿ replace system caused

by inadequate draft due to environmental conditions, down
drafts, tight sealing construction of the structure, or mechan-
ical exhausting devices which will create a negative air pres-
sure within the structure where the

¿ replace is located.

A. Understanding Vent Problems

If smoke spillage occurs from a

¿ replace opening when the

door is open and the proper chimney height,

À ue size, and

con

¿ guration requirements for the installation have been

met, there is either a leakage in the

À ue, a blockage in the

À ue, or some condition is in effect to draw smoke from the
¿ replace into the house. Understanding and differentiating
the conditions which can cause each of these kinds of spill-
age problems is essential to their solution.

• Flue

Leakage

Check for improperly connected

À ue joints or a damaged

À ue joint in the chimney system. Such leakage would
reduce draft (air would be drawn in through the leaks rather
than through the

¿ replace). The result might be dif¿ cult

start-up and smoky

¿ res that might spill if other adverse

draft conditions accompany this problem.

• Flue

Blockage

The damper should be open.