Warning, Caution – Heat & Glo Fireplace EXCLAIM-36T-C User Manual

Page 29

Advertising
background image

Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06

29

D. Flue Damper

The

À ue damper must be in full open position, and is oper-

ated by moving the handle up toward the top of the

¿ replace.

Before lighting the

¿ re, verify this by looking up from the in-

side of the

¿ replace. Always operate this ¿ replace with the

damper fully open. Please note: Down drafts, obstructions,
damaged or poor (wet) fuels can cause smoke spillage.

See Figure 9.1 for location and operation.

FULLY OPEN

CORRECT

PARTLY CLOSED

INCORRECT

PARTLY OPEN

INCORRECT

FULLY CLOSED

CORRECT

Figure 9.2

Proper Operating Positions of Bi-fold Doors

Fire Risk
Close

¿ rescreen when burning ¿ replace.

Do not use

¿ rescreen or glass doors to

hold burning material in

¿ replace.

Firescreen controls sparks.
Glass may break or burning material may
roll out.

WARNING

Fire Risk
Smoke Risk
Doors must be fully opened or fully closed

when operating

¿ replace.

Partially opened doors may draw

À ame, smoke

or heat from

¿ replace.

WARNING

Asphyxiation Risk
Fire Risk
Open damper to operate

¿ replace.

Closed damper will over-

¿ re ¿ replace and

prevent venting of combustion gases.

WARNING

B. Outside Air

A source of air (oxygen) is required in order for combustion
to take place. Whatever air is consumed by the

¿ re must be

replaced through cracks around windows, under doors, etc.
Most newly constructed houses or existing homes

¿ tted with

tightly sealed doors and windows are relatively air tight. In
this case, an outside air source must be made available to
feed combustion air from outside the home.

An outside air control handle allows you control of the out-
side air inlet if your

¿ replace is equipped with this option.

Use of outside air for combustion is highly recommended to
conserve heated air within the structure and to provide make
up air to keep the

¿ replace venting properly.

This

¿ replace will operate correctly only if adequate ventila-

tion is provided to allow proper draft to the

¿ replace sys-

tem.

See Figure 9.1 for location and operation.

CAUTION

Outside air control handle is HOT. Adjust before lighting
¿ re.

C. Clear Space Near the Fireplace

Combustible materials must not be stored on the hearth ex-
tension. Room furnishings such as drapes, curtains, chairs
or other combustibles must be at least 4 ft (1.22 m) from the
open front of the

¿ replace.

E. Firescreen

A

¿ rescreen is always provided to control sparks. It must

be closed whenever the

¿ replace is in use. Glass doors or

¿ rescreens must not be used to hold burning material in-
side the

¿ replace. Only those glass doors speci¿ cally tested

and listed for use with the speci

¿ c ¿ replace model should be

used. Screens should be closed when the glass doors are
closed.

F. Glass Doors

Most ef

¿ cient ¿ replace operation using glass doors is with

the doors open. When the doors are open the screen must
be closed. Only Hearth & Home Technologies glass doors
may be used. See Figure 9.2 for proper glass door opera-
tion.

Advertising