Practical Examples of DR

4-19

9. Check the status of all related domains.

Execute the showdcl(8) command to display domain information, and then
check the operation status of all related domains. Based on the operation status of
the domain, determine whether to perform the DR operation or reboot the
domains.

10. Add the new system board to the domain.

Execute the addboard(8) command in the domain to add the new system board.

11. Check the status of the related domains and system boards.

Execute the showdcl(8) command to check the operation status of related
domains, and then execute the showboards(8) command to check the status of
related system boards.

In this example, domain #1 is booted by power-on in this stage.

XSCF> showdcl -a

DID

LSB

XSB

Status

00

Running

00

00-0

01

01-0

02

01-1

-------

01

Powered Off

00

01-2

01

01-3

XSCF> addboard -c configure -d 0 01-0 01-1

XSCF> poweron -d 1

XSCF> showdcl -a

DID

LSB

XSB

Status

00

Running

00

00-0

01

01-0

02

01-1

-------

01

Running

00

01-2

01

01-3