SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007

Memory operation refused: dr@0:SBX::memory

[Explanation] The DR operation is refused.

[Remedy] Respond in the manner directed by the other message.

Memory operation cancelled: dr@0:SBX::memory

[Explanation] The DR operation is canceled.

[Remedy] Respond in the manner directed by the other message.

No device(s) on board: dr@0:SBX

[Explanation] There may be inconsistency in the system.

[Remedy] Please contact customer service.

[Output] Console and Standard Output

Non-relocatable pages in span: dr@0:SBX::memory

[Explanation] There is non-relocatable (kernel) memory on the system board.

[Remedy] The target board with kernel memory cannot be disconnected by DR. It
depends on the hardware model if you can remove a kernel memory board or
not.

Operator confirmation for quiesce is required: dr@0:SBX::memory

[Explanation] There is non-relocatable (kernel) memory on the board.

[Remedy] The target board with kernel memory cannot be disconnected by DR.

[Output] Console and Standard Output

Unexpected internal condition: drmach.c #

[Explanation] There may be inconsistency in the system.

[Remedy] Please contact customer service.

[Output] Console and Standard Output

Unexpected internal condition: SBX

[Explanation] The attempt to call OBP failed.

[Remedy] Repeat the action. If this error message appears again, please contact
customer service.

[Output] Console and Standard Output

Device busy: dr@0:SBX::cpuY

[Explanation] CPU Y on system board X is busy during release operation.

Advertising