Fujitsu Siemens Computers SPARC Enterprise M8000 User Manual

Page 71

Advertising
background image

Chapter 3

DR User Interface

3-9

The following examples show displays of the showboards(8) command

Example 1

: Display of information on all system boards

Test

Diagnostic status of system board

Unmount

The system board is not mounted or cannot be
recognized because it is faulty.

Unknown

The system board is not being diagnosed.

Testing

testing.

Passed

The system board was tested, and passed.

Failed

A system board error was tested, and failed.
The system board cannot be used or has been
degraded.

Fault

Normal/abnormal status of system board

Normal

Normal.

Degraded

Components have been degraded, but the system
board is operating. Degraded here means that a
system board included in the corresponding
component is faulty

.

Failed

The system board cannot operate because of an error.

COD

Indication of whether the system board is a COD board.

n

The board is not a COD board.

y

The board is a COD board.

XSCF> showboards -a

XSB

DID(LSB)

Assignment

Pwr

Conn

Conf

Test

Fault

------------------------------------------------------------------

00-0

00(00)

Assigned

y

y

y

Passed

Normal

00-1

00(01)

Assigned

y

n

n

Passed

Degraded

00-2

SP

Available

y

n

n

Unknown

Normal

00-3

01(15)

Assigned

y

y

y

Passed

Normal

TABLE 3-8

Items of System Board Information to be Displayed (Continued)

Display items

Description

Advertising
This manual is related to the following products: