Chapter 4

Practical Examples of DR

4-7

If you need to change the PSB configuration, use the setupfru(8) command. If
the system board to be added is not registered in the DCL, register the system
board in the DCL of the target domain by using the setdcl(8) command.

4. Add the new system board.

Execute the addboard(8) command to add the system board to the move-
destination domain.

5. Check the status of the domain and added system board.

When the addboard(8) command ends normally, execute the showdcl(8)
command to check the operation status of the domain, and then execute the
showboards

(8) command to check the status of the added system board.

If the addboard(8) command completes abnormally or leaves the board in an
unwanted status, refer output messages to identify the problem, then correct it.

XSCF> showboards -a

XSB

DID(LSB)

Assignment

Pwr

Conn

Conf

Test

Fault

----------------------------------------------------------------

00-0

00(00)

Assigned

y

y

y

Passed

Normal

01-0

SP

Available

y

n

n

Passed

Normal

XSCF> addboard -c configure -d 0 01-0

XSCF> showdcl -d 0

DID

LSB

XSB

Status

00

Running

00

00-0

01

01-0

XSCF> showboards -d 0

XSB

DID(LSB)

Assignment

Pwr

Conn

Conf

Test

Fault

------------------------------------------------------------------

00-0

00(00)

Assigned

y

y

y

Passed

Normal

01-0

00(01)

Assigned

y

y

y

Passed

Normal