Message Meaning and Handling

A-31

[Remedy] Find out the cause of the DR failure referring monitoring message and
console message. Try again after taking out cause.

Invalid parameter.

[Explanation] There is an error in the specified argument or operand.

[Remedy] Confirm the specified argument or operand and execute the command
once again.

Permission denied.

[Explanation] Do not have privilege.

[Remedy] Confirm the user privilege and the command privilege. In the case of
high-end servers, please also confirm whether command is executed by XSCF on
standby side.

The current configuration does not support this operation.

[Explanation] Cannot execute the command in the current configuration, or it is
not supported.

[Remedy] Confirm the current hardware configuration and support status.

A hardware error occurred. Please check the error log for

details.

[Explanation] Hardware error occurred. Please confirm monitoring message and
the error log.

[Remedy] Find out the cause of the DR failure referring monitoring message and
error log. Replace the failure component.

An internal error has occurred. Please contact your system

administrator.

[Explanation] DR failed. There is a possibility that DR failed because of an
internal error in XSCF.

[Remedy] Find out the cause of the DR failure referring monitoring message and
error log. Please also confirm the XCP version.

Timeout detected during self-test of XSB#XX-X.

[Explanation] Because the hardware diagnosis in DR did not complete, a timeout
occurred. There is a possibility that a hardware error occurred.

[Remedy] Find out the cause of the DR failure referring to the monitoring
message and error log. Replace the failed component.

XSB#XX-X will be assigned to DomainID X. Continue? [y|n]: