SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007

Operation already in progress: dr@0:SBX::cpuY

[Explanation] The operation on cpu Y on system board X is in progress.

[Remedy] Repeat the action. If the problem still exists, please contact customer
service.

[Output] Console and Standard Output

dr_move_memory: failed to quiesce OS for copy-rename

[Explanation] There is a task not suspended in the process.

[Remedy] Repeat the action. If this error message appears again, please contact
customer service.

[Output] Console and Standard Output

No available memory target: dr@0:SBX::memory

[Explanation] The system board cannot be detached because it contains kernel
memory and there is no available target memory board.

[Remedy] Add new system board and then try the detach operation again.

[Output] Console and Standard Output

Unsafe driver present: <driver name|major #> ...

[Explanation] DR driver found DR unsafe drivers in the system.

[Remedy] Unload the unsafe drivers and try the DR operation again.

[Output] Console and Standard Output

Device failed to resume: <driver name|major #> ...

[Explanation] Devices on the list failed to resume

[Remedy] Please contact customer service.

[Output] Console and Standard Output

Device failed to suspend: <driver name|major #> ...

[Explanation] Devices on the list failed to suspend

[Remedy] Please contact customer service.

[Output] Console and Standard Output

Operation not supported: ERROR

[Explanation] Invalid operation.

[Remedy] Repeat the action. If this error message appears again, please contact
customer service.