A.2.6 showdevices, A.2.6, Showdevices – Fujitsu Siemens Computers SPARC Enterprise M8000 User Manual

Page 150: A–34

Advertising
background image

A-34

SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007

The specified parameter is not supported in this model.

[Explanation] Unsupported parameter in this server is specified. For this reason,
the command was canceled.

[Remedy] Confirm the specified parameter and the server model, and execute the
command once again.

Invalid parameter.

[Explanation] There is an error in the specified argument or operand.

[Remedy] Confirm the specified argument or operand and execute the command
once again.

Permission denied.

[Explanation] Do not have privilege.

[Remedy] Confirm the user privilege and the command privilege. In the case of
high-end servers, please also confirm whether command is executed by XSCF on
standby side.

The current configuration does not support this operation.

[Explanation] Cannot execute the command in the current configuration, or it is
not supported.

[Remedy] Confirm the current hardware configuration and support status.

An internal error has occurred. Please contact your system

administrator.

[Explanation] DR failed. There is a possibility that DR failed because of an
internal error in XSCF.

[Remedy] Find out the cause of the DR failure referring monitoring message and
error log. Please also confirm the XCP version.

A.2.6

showdevices

XSB#%s is not currently running.

[Explanation] The system was not able to get some parameter for the XSB.

[Remedy] Confirm the information for the XSB via the showboards command.

cannot get device information from DomainID.

[Explanation] The system was unable to collect the requested information from
the domain.