Sensor testing – FARGO electronic DTC500 User Manual

Page 248

Advertising
background image

RESTRICTED USE ONLY

Fargo Electronics, Inc.

DTC500 Series Card Printer/Encoders User Guide (Rev. 5.0)

248

Sensor Testing

Step

Procedure

1

Check the voltage to determine if a Sensor is working.

2

a. Test the voltage of each Sensor using ground (GRD = Chassis) to the correct

pin on each connector. See the Sensor Location and Voltages table on the
next page).

b. Block a slot Sensor with a card.

c. Cover a reflective Sensor with a card.

3

a. Troubleshoot the Ribbon Sensor by using the RibbonTraq marks on the

Ribbon and Film to cover the Ribbon and Film Sensors. (Note: The numbers
indicate the location on J16, as shown in the Sensor Location and
Voltages
table on the next page).

b. Open the upper module to find the Ribbon Sensor orientation. (Note: The

numbers indicate the location on J16, as shown in the Sensor Location and
Voltages
table on the next page.)

Advertising