FARGO electronic DTC500 User Manual

Page 67

Advertising
background image

RESTRICTED USE ONLY

Fargo Electronics, Inc.

DTC500 Series Card Printer/Encoders User Guide (Rev. 5.0)

67

Troubleshooting the LCD Messages (continued)

Message

Cause

Solution

EE Checksum
Error

Indicates that the permanent
circuit board memory is bad.

See Resolving the EE Checksum
Error in Section 7, page 246.

EE Memory Error

Indicates that the permanent
circuit board memory is bad.

See Resolving the EE Memory Error
in Section 7, page 246.

Ejecting Used
Card

Indicates that the system
Firmware has detected a
card already in the Printer.

This card has been ejected; however,
it may contain encoded data and
should be disposed of in a proper
manner.

Failed To
Initialize

Indicates that an unexpected
hardware error has occurred.

See Board Errors in Section 7, page
246.

Flipper Alignment

Indicates that the Printer is
unable to align the Flipper
table.

See Resolving the Flipper Alignment
Error Message in Section 2, page
108.

FPGA

Indicates that an unexpected
hardware error has occurred.

See Resolving the FPGA Error in
Section 7, page 247.

FPGA Load Fail

Indicates that an unexpected
hardware error has occurred.

See Resolving the FPGA Error in
Section 7, page 247.

FPGA Timeout

Indicates that an unexpected
hardware error has occurred.

See Resolving the FPGA Error in
Section 7, page 247.

Head Lift

Indicates that the Printer was
unable to raise or lower the
Printhead.

See Resolving the Headlift Error
Message in Section 2, page 105.

Continued on the next page