4 stp hello, Stp hello – FUJITSU XG Series P3NK-4452-01ENZD User Manual

Page 220

Advertising
background image

XG Series User's Guide

Chapter 5 Command Reference

STP Information

220

5.8.1.4

stp hello

Function

Set a Hello message transmission interval.

Available Model

XG0224 / XG0448 / XG2600

Syntax

stp hello <time>

Options

<time>
• Transmission interval

Specify a transmission interval of configuration BPDU to be sent periodically after this
device becomes a root bridge, within the range of 1 to 10 seconds. The unit will be s
(second).

Use Mode

Configuration mode (admin class)

Explanation

Specify a transmission interval of configuration BPDU to be sent when this device
functions as a root bridge.
This setting is disabled when this device does not function as a root bridge even if it uses
an STP.

Caution

<time> checks the relationship with the definition value of stp age <max_age>.
• Check with max age time

max age time > = 2

× (hello time + 1.0 second)

If the definition value is invalid, the set values of <max_age>, <delay_time>, and <time>
will be disabled.
The following shows definition conditions that are available for checking the relationship
between <max age>, <delay_time>, and <time>.
2

× (forward delay time - 1.0 second) >= max age time >= 2 × (hello time + 1.0 second)

Default

It is assumed that 2 seconds are set for a transmission interval of configuration BPDU.

stp hello 2s

Advertising