18 remote request receiving register (rrtrr), Register function – FUJITSU F2MCTM-16LX User Manual

Page 490

Advertising
background image

474

CHAPTER 21 CAN CONTROLLER

21.4.18

Remote Request Receiving Register (RRTRR)

After a remote frame is stored in the message buffer (x), RRTRx becomes 1 (at the same
time as RCx setting to 1).

■

Register Configuration

Figure 21.4-18 Configuration of the Remote Request Receiving Register (RRTRR)

■

Register Function

●

Conditions for RRTRx = 0

•

Write 0 to RRTRx.

•

After a received data frame is stored in the message buffer (x) (at the same time as RCx setting to 1).

•

Transmission by the message buffer (x) is completed (TCx of the transmission complete register (TCR)

is 1).

Writing 1 to RRTRx is ignored.

1 is read when a Read Modify Write instruction is performed.

Note:

If setting to 1 by completion of the receive operation and clearing to 0 by writing occur at the same

time, the bit is set to 1.

Address

bit15

bit14

bit13

bit12

bit11

bit10

bit9

bit8

RRTRR1(Upper)

CAN1:

00008B

H

RRTR15

RRTR14

RRTR13

RRTR12

RRTR11

RRTR10

RRTR9

RRTR8

Reset value
0 0 0 0 0 0 0 0

B

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

Address

bit7

bit6

bit5

bit4

bit3

bit2

bit1

bit0

RRTRR1(Lower)

CAN1:

00008A

H

RRTR7

RRTR6

RRTR5

RRTR4

RRTR3

RRTR2

RRTR1

RRTR0

Reset value
0 0 0 0 0 0 0 0

B

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W : Read/Write

Advertising