Fan and Heater

VANE AXIAL GAS HEATER SPECIFICATIONS

BTU's Gauge Pressure (PSI) Natural Gas Models (Approximate)

High Temperature

7

1204750
1881456
2487940
2708640

6

1115380
1741920
2302800
2507090

5

1016880
1587790
2099420
2285470

4

909260

1419980
1876896
2043790

3

787970

1231200
1627920
1772020

2

644780

1006850
1331520
1450080

1

454180
710450
938450

1022350

Operating Pressure (PSI)

Diameter

18"
24"
26"
28"

Low Temperature

7

383040
470590

6

353860
435936

5

322850
397632

4

289100
355680

3

250800
308260

2

205200
251710

1

144100
177840

Operating Pressure (PSI)

Diameter

18"

24-28"

60

1
1

low-temp

1
1

low-temp
low-temp

2
1
1

low-temp

1
1
1
1

low-temp

1
1
1
1

low-temp

Fan Model

3HP-18"

7HP-24"

10HP-24"

15HP-26"

15HP-28"

Heat Rise Degrees F

Static

Pressure

1"
2"
3"
1"
2"
3"
4"
1"
2"
3"
4"
1"
2"
3"
4"
5"
1"
2"
3"
4"
5"

80

1
1

low-temp

2
1

low-temp
low-temp

2
2
1
1
2
1
1
1

low-temp

2
2
1
1

low-temp

100

2
1
1
2
1
1

low-temp

4
3
1
1
2
2
2
1
1
3
2
2
1
1

120

2
1
1
3
2
1
1
5
3
2
1
3
3
2
1
1
4
3
2
1
1

140

3
2
1
4
2
1
1
6
4
2
1
4
3
3
2
1
5
4
3
2
1

160

3
2
1
5
3
1
1
7
6
3
2
5
4
3
2
1
7
5
4
2
2

180

4
3
1
6
4
2
1
8
7
4
2
7
5
4
3
2
8
6
5
3
2

Gauge Pressure (Psi) Required To Maintain Temperature (Approximate)