Operating procedure, Programming set points – GSI Outdoors PNEG-377 User Manual

Page 43

Advertising
background image

43

Fan and Heater

Programming Set Points

Multiple heaters may be done at any heater control console. The informa-
tion programmed is automatically transmitted to all other heaters when the
programming is complete.

Hi Limit Set Point--The upper left cursor is flashing indicating the

mode. If the plenum temperature increases above this point, the flame is
shut off--"OFF-CYCLE" is displayed on screen.

Cycle Set Point--The upper 2nd from left cursor is flashing indicating

the mode. If the dryer is not a hi-lo dryer, this function is skipped. If
the plenum temperature increases above this point, the flame reduces to
"LO-FLAME".

Humidity Set Point--The upper 2nd from right cursor is flashing indi-

cating the mode. If the humidity is above this point the dryer operates

Depressing the "PROGRAM"
switch (lower left) causes the dis-
play to enter the program mode.
Each item below is programmed by
using the up and down arrow
switches. Holding down these up
and down arrow switches for about
2 seconds will cause the numbers to
increase/decrease rapidly until the
switch is released. When finished
programming an item, depressing the
"PROGRAM" switch again will
cause the new setting to be entered
into memory, and the display will ad-
vance to the next function to be pro-
grammed.

Programming may be done at

anytime (unless an error condi-
tion exists) even while the dryer
is in operation.

Programming a system with

The limits are continuously

checked during the drying operation.
A limit switch open or any other er-
ror condition will cause the dryer to
shutdown, and the fan will be shut-
down. If a limit opens, or an er-
ror condition occurs during dry-
ing, the control will lockup in the
error display mode. Power must
be shut off and back on to the
control to clear the error condi-
tion--even if the error or limit
that caused the shutdown has
been corrected.
This is to keep the
display locked up with the condition
that caused the error, allowing the
operator time to determine what
caused the shutdown.

normally--flame on and off at the high limit and cycle set points. If the
humidity is below this point the dryer goes into the "OFF-CYCLE" mode.

Temperature Differential--The upper right cursor is flashing indicating

the mode. If the flame shuts off because the temperature is greater than the
high limit set point, the temperature must fall below the (Set Point minus Tem-
perature Differential) for the flame to come back on.

Programming the high-limit set point.

OPERATING PROCEDURE

Advertising