2nd heater installation – GSI Outdoors PNEG-377 User Manual

Page 71

Advertising
background image

71

Fan And Heater

2ND HEATER INSTALLATION

For Units using HF-7100 Control Board

2nd Heater Control is Available with the HF-7100 heater control board. For Standard units (1) TD-

100282 Relay must be installed. For HI-LO units (2) TD-100282 Relay and (1) TD-100283 Relay

base must be installed. INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRI-

CIAN. When points are called out in instructions they are in reference to points on drawing below

text.

Installation (Standard Units)

1.

Plug (1) TD-100282 Relay into empty

socket on HF-7100 Control Board in Main

Heater.

2.

Run (2) wires from main heater (heater that

thermostat is connected to) to 2nd heater.

3.

Connect 2 wires to terminals 1 and 2 (Points

C and D) of 2nd heater control terminal strip

in Main heater.

4.

Connect other end of these wires to termi-

nals 4 and 5 (Points F and E) on lower left

hand corner of HF-7100 board in 2nd heater.

Installation (HI-LO Units)

1.

Plug (1) TD-100282 Relay into empty

socket on HF-7100 Control board in Main

heater.

2.

Install TD-100283 Relay base in main

heater.

3.

Run 1 wire from CYCLE (Point A ) to

terminal 13 on Relay Base. Run 1 wire from

COMM (Point B) to terminal 14 on relay

base.

4.

Run (4) wires from Main Heater (Heater

that thermostat is connected to) to 2nd

Heater.

5.

Connect 2 of the wires to terminals 9 and

5 of TD-100283 Relay base in main heater.

6.

Connect other end of

these wires to terminals 2 and 3

(Points G and H) on lower left

hand corner of HF-7100 board

in 2nd heater.

7.

Connect other 2 wires to

terminals 1 and 2 (Points D and

C) of 2nd heater control termi

nal strip in Main heater.

8.

Connect other end of these

wires to terminals 4 and 5

(Points E and F) on lower left

hand corner of HF-7100 board

in 2nd heater.

9.

Install TD-100282 Relay into

TD-100283 Relay base in main

heater.

B

C

D

A

E

F

G

H

Advertising