59

Fan and Heater

TROUBLE-SHOOTING FLOW CHART

This chart should be used step by step to troubleshoot heater if heater does not start immediatly after

turning on switch. This troubleshooting flow chart requires use of a voltmeter to check for 110 volts

on designated terminals on terminal strip in heater. Always use voltmeter to check between termi-

nals that are designated not between terminals and ground.

Voltage

terms 1 and 8

Check incoming

power supply to

heater

Voltage

terms 2 and 8

Fuse blown or on/

off switch bad

Voltage

terms 4 and 8

Reset button

tripped or bad

Check

thermostat

Voltage

terms 4 and 5

Voltage

terms 6 and 8

Voltage

terms 7 and 8

Voltage

terms 4 and 3

Open

Flame Probe

Housing

HI-Limit

tripped or bad

Replace

Terminal Strip

Check Vapor

HI-Limit

NO

NO

NO

NO

NO

NO

NO

YES

YES

YES

YES

YES

YES

YES