Fan and Heater

TRANSITION HI-LIMIT INSTALLATION

1. Mark location on transition

one (1) foot up from the bot-
tom (entrance collar) and cen-
tered in the transition.

2. Drill or knock out 7/8" diam-

eter hole on marked location.

3. Install transition hi-limit us-

ing supplied self drilling
screws.

Figure 2: The transition connecting the Vane Axial Heater to the bin with

the plenum sensor in place.

Plenum Thermostat

Mounting

The plenum thermostat is the 4 x
4 white box with knob that is
preconnected to heater when
heater is ordered with thermostat.

1. 24" to the right side of the

transition, drill one

3

/

8

" hole

(high temp) or 1

1

/

2

" hole (low

temp) in the center of the ple-
num in a valley (4.00" corru-
gation) or hill (2.66" corruga-
tion) on bin sidewall.

2. Insert the probe through the

hole.

3. Position the housing so that

the tabs are vertical, and the
cord exits the housing hori-
zontally.

Plenum thermostat mounting on bin wall.

5. Caulk between the housing

and the sidewall to seal.

4. Use 4 self drilling screws to

mount the housing to the bin
sidewall.

Transition Hi-Limit Installation