Fan and Heater

Adjusting the Air Pressure Switch

1.

Air pressure switch must be adjusted so

that it will activate with lowest level of

grain that will be dryed in bin.

2.

Put grain in bin to level desired (low).

3.

With heater on and fan off display on

heater should read "no airflow".

4.

Start fan. Heater display should now read

"airflow".

5.

If display does not read "airflow" remove

cap from adjustment port and slowly turn

screw counter clockwise until display does

read "Airflow". Figure C

6.

Shut fan off display should read "no air

flow" when fan gets to half speed. If not

repeat step 5.

Figure C