2nd heater installation – GSI Outdoors PNEG-377 User Manual

Page 66

Advertising
background image

66

Fan And Heater

2ND HEATER INSTALLATION

For Units using HF-7100 Control Board

Manufactured after September 1. 1993

2nd Heater Control is Available with the HF-7100 heater control board. For Standard units no extra

parts are required. For HI-LO units (1) TD-100282 Relay must be installed. INSTALLATION

SHOULD BE MADE BY A QUALIFIED ELECTRICIAN. When points are called out in instruc-

tions they are in reference to points on drawing below text.

Installation (Standard Units)

1.

Run (2) wires from Main Heater (Heater that

thermostat is connected to) to 2nd Heater.

2.

Connect 2 wires to terminals 3 and 4 (Points

B and A) of 2nd heater control terminal strip

in Main heater.

3.

Connect other end of these wires to termi-

nals 4 and 5 (Points F and E) on lower left

hand corner of HF-7100 board in 2nd heater.

Installation (HI-LO Units)

1.

Plug (1) TD-100282 Relay into empty

socket on HF-7100 Control board in Main

Heater.

2.

Run (4) wires from Main Heater (Heater

that thermostat is connected to) to 2nd

Heater.

3.

Connect 2 of the wires to terminals 3 and 4

(Points B and A) of 2nd Heater control

terminal strip in Main heater.

4.

Connect other end of these wires to termi-

nals 4 and 5 (Points F and E) on lower left

hand corner of HF-7100 board in 2nd

heater.

5.

Connect other 2 wires to terminals 1 and 2

(Points D and C) of 2nd heater control

terminal strip in Main heater.

6.

Connect other end of these wires to termi-

nals 2 and 3 (Points Hand G) on lower left

hand corner of HF-7100 board in 2nd

heater.

USED ON HI-LO UNITS ONLY

A

B

C

D

E

F

G

H

Advertising