46

Fan and Heater

FACTORY CONFIGURATION

Configuration Dip

Switches (Normally Done

At GSI)

Stand alone heater
with no slaves, all
dip switches in the
off state.

These switches are used to config-
ure the heater control for various
types of heaters.

Multiple heaters connected together through the serial link.

Master with one
slave-dip switch 7
on/all others off.

Slave #1-dip switch
one and three on/all
others off.

Master with two
slaves-dip switch 8
on/all others off.

Slave #2-dip switch
two and three on/all
others off.

Master with 3
slaves-dip switch 7
& 8 on/all others
off.

Slave #3-dip switch
one, two and three
on/all others off.

The backside of the control board, showing the dip switch placement.

Dip switch number 3 by-passes air
pressure switch when turned on.
This switch should only be used
while trouble-shooting heater.
Never leave Heater running
with air pressure switch by-
passed.