Fan and Heater

Adjusting the vaporizer coil on a liquid propane model. The top photo shows

the setting in, and the bottom photo shows the coil out.

Adjusting The Vaporizor

The display will indicate "FLAME"
when flame is sensed. If no flame
is sensed, the "FLAME" message
will be off. The display indicates
what part of the cycle it is in. If the
unit is a hi-lo dryer, the display will
indicate whether it is in the "HI-
FLAME" or "LO-FLAME" part of
the cycle. (See "programming set
points" page 21 for setting the hi-lo
flame temperature). If the tempera-
ture is above the high temperature set-
ting, the flame will be off, the "FLAME"
message will be out and the display
will be flashing "OFF-CYCLE".

If the flame is shut off because

of the humidity sensor (humidistat),
the display flashes "OFF-CYCLE
HUMIDISTAT".

Running The Dryer

1. Vaporizer should be adjusted so

the vapor pipetrain runs warm
to the touch (100°-120°F).

2. Loosen 5/16" bolt on adjust-
ment bracket.

3. Swivel vaporizer away from

flame if running too hot, closer
to flame if too cold.

4. Move vaporizer only 1" at a time

and allow a few minutes for
tem perature to equalize.

5. Tighten 5/16" bolt and watch

heater run for several minutes
to verify adjustment.

OPERATING PROCEDURE