Chi-town heater specifications, Fan and heater – GSI Outdoors PNEG-377 User Manual

Page 32

Advertising
background image

32

Fan and Heater

CHI-TOWN HEATER SPECIFICATIONS

Btu's Per Gauge Pressure (Psi) Natural Gas Models (Approximate)

MED TEMPERATURE

Operating Pressure (PSI)

1

382,000

Diameter

26"

2

541,000

3

662,000

4

763,000

5

854,000

6

936,000

7

1,011,000

8

1,083,000

LOW TEMPERATURE

Operating Pressure (PSI)

1

158,000

Diameter

26"

2

225,000

3

275,000

4

317,000

5

354,000

6

388,000

7

420,000

8

449,000

Gauge Pressure (Psi) Required To Maintain Temperature (Approximate)

20

1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
1
2
2
2
1
3
2
2
2

Static

Pressure

2"
3"
4"
5"
2"
3"
4"
5"
3"
4"
5"
6"
3"
4"
5"
6"
4"
6"
8"

10"

4"
6"
8"

10"

Fan Model

10HP

15HP

20HP

25HP

30HP

40HP

Heat Rise Degrees F

30

1
1
1
1
2
2
2
1
2
2
2
2
3
3
3
3
4
3
3
2
6
5
4
3

40

2
2
2
2
3
3
2
2
4
4
3
3
6
5
5
4
7
5
5
3
8
8
7
5

50

3
3
2
2
4
4
4
3
6
5
5
5
8
8
7
7

8
7
5

7

60

4
4
3
3
6
6
5
4
8
8
7
7

7

70

5
5
4
4
8
7
7
5

8

80

7
6
6
5

8
7

Advertising